SCOR WG 142: Quality Control Procedures for Oxygen and Other Biogeochemical Sensors on Floats and Gliders. Recommendations on the conversion between oxygen quantities for Bio-Argo floats and other autonomous sensor platforms. Version 1.1
View/ Open
Average rating
votes
Date
2018Author
Bittig, Henry
Körtzinger, Arne
Johnson, Ken
Claustre, Hervé
Emerson, Steve
Fennel, Katja
Garcia, Hernan
Gilbert, Denis
Gruber, Nicolas
Kang, Dong-Jin
Naqvi, Wajih
Prakash, Satya
Riser, Steven
Thierry, Virginie
Tilbrook, Bronte
Uchida, Hiroshi
Ulloa, Osvaldo
Xing, Xiaogang
Status
PublishedPages
6pp.
Metadata
Show full item recordAbstract
As Argo has entered its second decade and chemical/biological sensor technology is improving constantly, the marine biogeochemistry community is starting to embrace the successful Argo float program. An augmentation of the global float observatory, however, has to follow rather stringent constraints regarding sensor characteristics as well as data processing and quality control routines.
Owing to the fairly advanced state of oxygen sensor technology and the high scientific value of oceanic oxygen measurements (Gruber et al., 2010), an expansion of the Argo core mission to routine oxygen measurements is perhaps the most mature and promising candidate (Freeland et al., 2010).
In this context, SCOR Working Group 142 “Quality Control Procedures for Oxygen and Other Biogeochemical Sensors on Floats and Gliders” (www.scor-int.org/SCOR_WGs_WG142.htm) set out in 2014 to assess the current status of biogeochemical sensor technology with particular emphasis on float-readiness, develop pre- and.....
Publisher
IfremerPlouzane, France
Document Language
enMaturity Level
TRL 8 Actual system completed and "mission qualified" through test and demonstration in an operational environment (ground or space)Best Practice Type
Standard Operating ProcedureDOI Original
10.13155/45915Citation
Bittig, H., Kortzinger, A., Johnson, K., Claustre, H., Emerson, S., Fennel K., Garcia H., Gilbert, D., Gruber, N., Kang, D-J., Naqvi, W., Prakash, S., Riser, S., Thierry, V., Tilbrook, B., Uchida, H., Ulloa, O., Xing, X. (2018) SCOR WG 142: Quality Control Procedures for Oxygen and Other Biogeochemical Sensors on Floats and Gliders. Recommendation for oxygen measurements from Argo floats, implementation of in-air-measurement routine to assure highest long-term accuracy.Version 1.1. Plouzane, France, Ifremer, 6pp. DOI: 10.13155/45915Collections