Show simple item record

dc.contributor.authorHeitsenrether, R.
dc.contributor.authorHensley, W.
dc.date.accessioned2018-12-12T18:48:42Z
dc.date.available2018-12-12T18:48:42Z
dc.date.issued2013
dc.identifier.citationHeitsenrether, R. and Hensley, W. (2013) Test and Evaluation Report for WaterLog® H-3612 Radar Sensor in CO-OPS Air Gap Applications. Silver Spring, MD, NOAA NOS Center for Operational Oceanographic Products and Services, 43pp & appendices. (NOAA Technical Report NOS CO-OPS 072). DOI: http://dx.doi.org/10.25607/OBP-137en_US
dc.identifier.urihttp://hdl.handle.net/11329/572
dc.identifier.urihttp://dx.doi.org/10.25607/OBP-137
dc.description.abstractIn 2005, the National Oceanic and Atmospheric Administration (NOAA) National Ocean Service (NOS) Center for Operational Oceanographic Products and Services (CO-OPS) completed the development, testing, and transition to operations of an air gap-bridge clearance measurement system for use in the CO-OPS Physical Oceanographic Real-Time System (PORTS®). The purpose of this measurement system is to provide real-time observations of the vertical distance from a bridge’s lowest steel to the mean water level surface below, commonly referred to as air gap. The observation provides vessel pilots with decision support information that can decrease the likelihood of vessel overhead allisions with bridges. This development and test effort was motivated and supported by several PORTS® customers who were concerned with growing bridge allision risks resulting from significant increase in vessel size and vessel traffic across several U.S. ports and harbors. Developed and transitioned to operations in 2005 by CO-OPS Ocean System Test and Evaluation Program (OSTEP), the air gap system employs a microwave band radar range sensor to measure the distance from a point on a bridge to the water surface below. The radar sensor selected for that system is a Miros model SM-094. Initial development efforts and several related reports and presentations clearly conveyed that microwave radar technology is the best choice for the PORTS® air gap measurement applications. OSTEP has continued test and development efforts with radar range sensors for other CO-OPS applications, partly because of the success of the PORTS® air gap system. From 2008-2011, OSTEP expended significant effort to test and evaluate four different brands of radar range sensors to assess their suitability for use as primary water level sensors throughout the CO-OPS National Water Level Observation Network (NWLON). Three years of additional field and lab testing has resulted in a significant increase in CO-OPS’ knowledge of microwave radar sensor technology, both through analysis of test data and hands-on field experience with sensors. Additional information about other available commercial-off-the-shelf sensor brands and models was also obtained through the effort. This wealth of knowledge gained through additional radar sensor testing for NWLON applications has been leveraged to support a number of improvements to existing operational air gap measurement systems. Recent improvements include enhanced laboratory test procedures and analysis tools, Sutron Xpert data collection platform software upgrades, and new mounting hardware designs. Most recently, the OSTEP team has identified the Design Analysis WaterLog® H-3612 microwave radar as a potential alternative PORTS® air gap sensor, based on test results for NWLON applications. This sensor, already used in some CO-OPS water level applications, offers many advantages over CO-OPS’ current operational sensor, the Miros SM-094. Motivated by the potential to improve existing PORTS® air gap systems, OSTEP conducted a series of laboratory and field tests on the WaterLog® H-3612 designed to assess the suitability for use in PORTS® air gap applications. All laboratory tests conducted indicate that the WaterLog® H-3612 meets CO-OPS operational standards. Field testing included the installation of a test WaterLog® sensor alongside an operational Miros SM-094 sensor at the PORTS® station on the Reedy Point, DE Bridge for eight months. WaterLog® and Miros sensors showed good agreement during the field test for air gap data collected and transmitted every 6 minutes. The monthly root mean squared deviation was less than 4 cm, and the monthly mean differences were all less than 6.2 cm; both values are well below the real-time air gap measurement accuracy requirement of ±15 cm, which CO-OPS established with prospective users during initial air gap system development efforts [1]. Based on laboratory and field test results included in this report, OSTEP has recommended use of the WaterLog® H-3612 radar sensor at CO-OPS operational air gap stations where the sensor’s maximum 70-m range is not expected to be exceeded.en_US
dc.language.isoenen_US
dc.publisherNOAA, NOS Center for Operational Oceanographic Products and Servicesen_US
dc.relation.ispartofseriesNOAA Technical Report NOS CO-OPS;072
dc.rightsCC0 1.0 Universal*
dc.rights.urihttp://creativecommons.org/publicdomain/zero/1.0/*
dc.titleTest and Evaluation Report for WaterLog® H-3612 Radar Sensor in CO-OPS Air Gap Applications.en_US
dc.typeReporten_US
dc.description.statusPublisheden_US
dc.format.pages43pp. & appendicesen_US
dc.description.refereedRefereeden_US
dc.publisher.placeSilver Spring, MDen_US
dc.subject.parameterDisciplineParameter Discipline::Physical oceanographyen_US
dc.subject.instrumentTypeInstrument Type Vocabulary::water level markersen_US
dc.rights.licensePublic Domain
dc.description.currentstatusCurrenten_US
dc.description.eovSea surface heighten_US
dc.description.bptypeBest Practiceen_US
dc.description.bptypeGuideen_US
obps.contact.contactemailcoops.webmaster@noaa.gov
obps.resourceurl.publisherhttps://tidesandcurrents.noaa.gov/pub.htmlen_US